DMR 2 Commands
:MEASure:SIGAnalyzer?
Description: Sets the active measurement to DMR 2 Analyzer, triggers a new
S412E PM
measurement and returns the numerical results. It is a combination of
the commands :CONFigure:SIGAnalyzer and
:READ:SIGAnalyzer?
For firmware v1.13 and prior, data is returned as 14 comma-separated
values in the following order and format:
Received Power (dBm as float or Watts as long long int or Volts as
long long int)
Frequency Error (Hz as float)
Mod Fid (% as float)
BER (% as float)
Symbol Dev (Hz as float)
CC (hex)
Symbol Rate Error (Hz as float)
Source Address (as integer)
FLCO (as integer)
CSBKO (as integer)
FID (as integer)
Target ID (as integer)
Talk group ID (as integer)
Base Station ID (as integer)
For firmware v1.14 and later, data is returned as 13 comma-separated
values in the following order and format:
Received Power (dBm as float or Watts as long long int or Volts as
long long int)
Frequency Error (Hz as float)
Mod Fid (% as float)
BER (% as float)
Symbol Dev (Hz as float)
CC (hex)
Symbol Rate Error (Hz as float)
Source UID (as integer)
Target ID (as integer)
Talk Group ID (as integer)
FID (as integer)
Call Type (as char)
Base Station ID (as integer)
If there is no valid measurement data, the instrument will return "--" in
that field.
The received power will be returned in the unit that is selected through
the Rx Units button on the front panel or with the command:
UNIT:POWer:RX. If the receiver unit has been set to dBm, the received
power is returned in dBm. If the unit is set to Watts, the received power
is returned in fW (10
is returned in fV (10
PN: 10580-00319 Rev. N
-15
W). If the unit is set to Volts, the received power
-15
V).