15-7 :MEASure Subsystem
:MEASure:SIGAnalyzer?
Description: Sets the active measurement to PTC Analyzer, triggers a new
15-14
measurement and returns the numerical results. It is a combination
of the commands :CONFigure:SIGAnalyzer and
:READ:SIGAnalyzer?
Data is returned as 8 comma-separated values in the following order
and format.
When the modulation type is set to 4FSK
([:SENSe]:DM:FORMat 4FSK):
Received Power (dBm as float or Watts as long long int or Volts as
long long int)
Frequency Error (Hz as float)
Mod Fid (% as float)
BER (% as float)
Symbol Dev (Hz as float)
Symbol Rate Error (Hz as float)
When the modulation type is set to DQPSK
([:SENSe]:DM:FORMat DQPSK):
Received Power (dBm as float or Watts as long long int or Volts as
long long int)
Frequency Error (Hz as float)
EVM (% as float)
BER (% as float)
IQ Imbalance (dB as float)
Symbol Rate Error (Hz as float)
Phase Error (degree as float)
Mag Error (% as float)
If there is no valid measurement data, the instrument will return
"--,--,--,--,--,--,--,--".
The received power will be returned in the unit that is selected through
the Rx Units button on the front panel or with the command:
UNIT:POWer:RX. If the receiver unit has been set to dBm, the received
power is returned in dBm. If the unit is set to Watts, the received power
is returned in fW (10
is returned in fV (10
PN: 10580-00319 Rev. N
-15
W). If the unit is set to Volts, the received power
-15
V).