[:Sense]:Correction:ckit Subsystem - Anritsu LMR Master S412E Programming Manual

An integrated, handheld multi-function land mobile radio test tool
Hide thumbs Also See for LMR Master S412E:
Table of Contents

Advertisement

VNA Commands

[:SENSe]:CORRection:CKIT Subsystem

This subsystem provides commands that modify and configure the device under test (DUT).
[:SENSe]:CORRection:CKIT:INFormation? <connector>
Description: Returns a string of information of the given calibration connector.
Cmd Parameter: NA (query only)
Query Parameter: <char> <connector>
Query Response: <block> (returns comma-delimitted ASCII format)
Front Panel Access: NA
S412E PM
<connector> defines the connector family. Valid connectors for
calibration line type COAX are as follows:
NMALe|NFEMale|KMALe|KFEMale|716Male|716Female|TNCMale|
TNCFemale|SMAMale|SMAFemale|USR1|USR2|USR3|USR4
Note that the connector must be for valid for the current calibration line
type.
Note that user 1, 2, 3, or 4 is based on the current calibration method.
The response begins with an ASCII header. The header specifies the
number of following bytes. It appears in the format #AX, where A is
the number of digits in X, and X is the number of bytes that follow
the header. Parameters are returned in comma-delimited ASCII format.
Each parameter is returned as "NAME=VALUE[UNITS]."
PN: 10580-00319 Rev. N
5-11 [:SENSe] Subsystem