NXDN Commands

12-10 :SOURce Subsystem

The commands in this subsystem control the internal signal source.
:SOURce:CORRection:OFFSet[:MAGNitude] <value>
:SOURce:CORRection:OFFSet[:MAGNitude]?
Description: Sets the power level offset for the NXDN signal generator. Please note
Cmd Parameters: <value>
Query Parameters: NA
Range: 100 dB Ext Loss to 100 dB Ext Gain
Default Value: 0 dB
Default Unit: dB
Example: To set the signal generator offset to 10 dB external gain:
Front Panel Access: Amplitude, Tx Power Offset
:SOURce:DM:PATTern <value>
:SOURce:DM:PATTern?
Description: Sets the signal generator pattern. The command only accepts the
Cmd Parameters: <value>
Query Parameters: NA
Range: 0 to Number of Patterns
Default Value: 0
Default Unit: NA
Example: To set the pattern to the 3rd pattern in the signal generator pattern list:
Front Panel Access: Setup, Tx Pattern
S412E PM
that changing this value will also cause the display of the Tx output
level to adjust to the new offset. For example, if the output level is set to
0 dBm and the level offset is then set to 10 dB external gain, the max
limit and value of the output level will be adjusted to 10 dBm. The
query returns a value from -100 to 100. A negative sign means external
gain and no sign means external loss.
:SOURce:CORRection:OFFSet -10
numerical value of the position the pattern is on the list (starting
from 0). To retrieve the numerical values attached to each pattern, use
:SOURce:DM:PATTern:LIST? The query returns a numerical value
corresponding to the position of the current Tx pattern in the pattern
list.
:SOURce:DM:PATTern 2