LTE Commands
:CONFigure:RF SUMMary|SPECtrum|ACLR|SEM
Title: Select RF Measurements
Description: This command configures RF measurements. It disables any other
Parameter: SUMMary|SPECtrum|ACLR|SEM
Front Panel Access: Measurements, RF, (Channel Spectrum, ACLR, Spectral Emission
:CONFigure SUMMary
Title: Set Measurement to LTE Summary
Description: Sets the measurement to LTE Summary. It disables any other active
Parameter: SUMMary
Parameter Type: <char>
Front Panel Access: Measurements, LTE Summary
S412E PM
active measurements. None of the instrument parameters are changed
by the execution of this command. Sets the instrument to single sweep
mode (:INITiate:CONTinuous OFF).Measurement settings can be
modified by using the [:SENSe] commands before initiating a
measurement.
Set measurement to one of the RF measurement screens. This can be
one of:
SUMMary:
RF measurement summary screen.
SPECtrum:
RF Channel Spectrum measurement screen.
ACLR:
ACLR measurement view.
SEM:
Spectral Emission Mask measurement.
Mask, RF Summary)
measurements. None of the instrument parameters are changed by the
execution of this command. (:INITiate:CONTinuous OFF).
Measurement settings can be modified by using the [:SENSe]
commands before initiating a measurement.