11-2 :CONFigure Subsystem

11-2
:CONFigure Subsystem
This set of commands prepares the instrument for the selected measurement. It disables any
currently-enabled measurements and activates the specified measurement.
Current instrument settings may be changed to default values. These changes are identified
with their respective measurement commands.
Sending a non-query :CONFigure command will change the Sweep setting from
Note
Run to Hold.
:CONFigure?
Description: :CONFigure? query returns the name of the measurement previously
Cmd Parameters: NA
Query Parameters: NA
Range: NA
Default Value: NA
Default Unit: NA
Example: To query the current measurement type:
Front Panel Access: Measurement
11-2
set up using a CONFigure command or a MEASure? query. The list
below shows the possible return values and the actual names of each
configuration.
Returns Value
SIGA
COV
CONT
BITC
:CONFigure?
PN: 10580-00319 Rev. N
Actual Name
P25p2 Analyzer
P25p2 Coverage
P25p2 Control
P25p2 Bit Capture
P25 Phase 2 Commands