11-8 :MMEMory Subsystem
:MMEMory:LOAD:TRACe <integer>,<filename>
Description: The instrument must be in the mode of the saved trace in order to recall
11-18
that trace. Use :INSTrument:SELect or :INSTrument:NSELect to
set the mode.
Recalls a previously stored measurement trace from the current save
location. The saved measurement trace to be loaded is specified by
<filename>. <filename> should be enclosed in either single quotes
(' ') or double quotes (" ") and should contain a file extension. Note that
the trace specified by <filename> should be available at the current
save location. Use the command MMEMory:MSIS to set the current save
location. The <integer> parameter is not currently used, but it must
be sent. Send a 1.
After recalling the data file, the unit is put into HOLD mode. Setting
the unit back to RUN mode will clear the recalled data, but keep the
recalled setup.
File name extensions:
".spa" for SPA measurement
".mna" for VNA and VVM measurements
".hipm" for HiPM measurements
".pm" for PM measurements
".cwsg" for CWSG measurements
".afp" for AM/FM/PM measurements
".ia" for Interference Analysis measurements
".cs" for Channel Scanner measurements
".wmxd" for WiMAX
".wmxe" for Mobile WiMAX