5-11 [:SENSe] Subsystem
[:SENSe]:CORRection:COLLect[:ACQUire] <cal steps>, <port_no>
[:SENSe]:CORRection:COLLect[:ACQUire]?
Description: Performs a measurement of the given steps. <cal steps> is the
Cmd Parameter: <char> <cal steps>, <port_no>
Query Parameter: <char> <cal steps>, <port_no>
Query Response: <string>
Front Panel Access: Shift-2 (Calibrate), Start Cal
Calibration Steps and Calibration Types
For each calibration Type,
used in command [:SENSe]:CORRection:COLLect[:ACQUire] <cal steps>,
<port_no>. The calibration steps are different for each calibration Method, and the port_no
is different for each calibration Type. For example, for calibration Type RFP1 and calibration
Method SOLT, the allowable <cal steps>, <port_no> settings are "OPEN,1",
"SHORT,1", and "LOAD,1". The steps that are not allowed are indicated by "—".
Table 5-6.
SOLT Calibration Method
Calibration Type
RFP1 (Full S
- Port 1)
11
TRFP (Response S
Path)
RRP1 (Response S
Port 1)
2PFP (1P2P S
, S
11
5-72
calibration step to be performed and must be one of the following
values:
OPEN|SHORT|LOAD|
THRU|ISOLation
<port_no> is the port number, 1. For calibration step OPEN, SHORT,
and LOAD, valid port number is 1. For calibration step THRU and
ISOLation, valid port number is 1 for Fwd.
Note that the calibration step must be valid for the given calibration
type and calibration method. Refer to
calibration steps for each type and method.
The query version of this command returns a string that consists of the
last calibration step measurement that was performed followed by the
port number. The calibration step and port number are delimited by a
comma. Note that if no calibration step has been processed, then this
command returns the string "NONE, 0".
Table 5-6
lists the allowable calibration steps and port_no to be
- Trans Response Fwd
21
- Reflection Response
11
- 1 Path 2 Port Fwd Path)
21
PN: 10580-00319 Rev. N
Table 5-6
OPEN
SHORT
LOAD
1
1
1
1
1
1
VNA Commands
for a list of valid
THRU
ISOL
1
1
1
1
1
1