Anritsu LMR Master S412E Programming Manual page 477

An integrated, handheld multi-function land mobile radio test tool
Hide thumbs Also See for LMR Master S412E:
Table of Contents

Advertisement

DMR 2 Commands
Cmd Parameters: <integer>,<filename>
Query Parameters: NA
Range: NA
Default Value: NA
Default Unit: NA
Example: To recall a measurement file:
Front Panel Access: Shift 7 (File), Recall Measurement
Control Channel, Bit Capture and IQ Data measurements can not be recalled on
Note
the instrument.
:MMEMory:STORe:STATe <integer>,<filename>
Description: Stores the current setup into the file specified by <filename>.
Cmd Parameters: <integer>,<filename>
Query Parameters: NA
Range: NA
Default Value: NA
Default Unit: NA
Example: To save a setup file:
Front Panel Access: Shift 7 (File), Save
S412E PM
".lte" for LTE measurements
".p25" for P25 measurements
".p252" for P25p2 measurements
".nxdn" for NXDN measurements
".dpmr" for dPMR measurements
".dmr2" for DMR 2 measurements
".ptc" for PTC measurements
".tetra" for TETRA measurements
".nbfm" for NBFM measurements
:MMEMory:LOAD:TRACe 1,"xxx.dmr2"
<filename> should be enclosed in either single quotes (' ') or double
quotes (" ") and should not contain a file extension. Use the command
MMEMory:MSIS to set the current save location. The <integer>
parameter is not currently used, but it must be sent. Send a value of 0.
:MMEMory:STORe:STATe 0,"xxx"
PN: 10580-00319 Rev. N
14-8 :MMEMory Subsystem
14-21