VNA Commands
:CALCulate:LIMit:POINt:Y <y-parameter>
:CALCulate:LIMit:POINt:Y?
Description: Sets the location of the active limit point on the y-axis at the specified
Cmd Parameter: <NRf> <y-parameter> (depends on display)
Query Response: <NR3> <y-parameter> (depends on display)
Default Units: Current active trace y-axis unit
Related Command: :CALCulate:LIMit:POINt:X
Front Panel Access: Shift 6 (Limit), Limit Edit, Amplitude
:CALCulate:LIMit[:STATe] OFF|ON|0|1
:CALCulate:LIMit[:STATe]?
Description: Turns the active trace currently selected limit line (upper or lower) ON
Cmd Parameter: <boolean> OFF|ON|0|1
Query Response: <bNR1> 0|1
Default Value: OFF or 0 (query returns 0 for OFF)
Example: To turn on the currently selected limit line:
Front Panel Access: Shift 6 (Limit), Limit State
S412E PM
location. Sending this command changes the Move Limit on the front
panel to Point if it is currently set to Limit. The <y-parameter> is
defined in the current y-axis. If no unit is specified with the
<y-parameter>, then the default unit is used. The query version of
the command returns the location of the active limit point on the y-axis.
If an error occurs, such as limit not ON, the query version of the
command returns an error code of –400. Limit line must be ON for the
command to be valid. Use :CALCulate:LIMit:TYPE to set the
currently active limit line.
or OFF. If the value is set to ON or 1, then the active trace selected limit
line is turned ON. If the value is set to OFF or 0, then the active trace
selected limit line is turned OFF. The query version of the command
returns a 1 if the active trace selected limit line is ON and returns a 0 if
it is OFF. Use :CALCulate:LIMit:TYPe to set the currently active
limit line.
:CALCulate:LIMit ON
:CALCulate:LIMit:STATe ON
:CALCulate:LIMit:STATe 1
To turn off the currently selected limit line:
:CALCulate:LIMit OFF
:CALCulate:LIMit:STATe 0
:CALCulate:LIMit 0
PN: 10580-00319 Rev. N