Anritsu LMR Master S412E Programming Manual page 104

An integrated, handheld multi-function land mobile radio test tool
Hide thumbs Also See for LMR Master S412E:
Table of Contents

Advertisement

4-14 [:SENSe] Subsystem
[:SENSe]:FSTRength:ANTenna <antenna>
[:SENSe]:FSTRength:ANTenna?
Title: Field Strength Antenna
Description: Selects an antenna from the antenna list to use for field strength
Note
An invalid selection will return a zero when queried.
Parameter: <antenna>
Default Value: 1
Related Command: :CONFigure:FSTRength
Front Panel Access: Shift-4 (Measure), Field Strength, Antenna
[:SENSe]:FSTRength:STATe OFF|ON|0|1
[:SENSe]:FSTRength:STATe?
Title: Field Strength Measurement State
Description: Sets the state of the field strength measurement, ON or OFF. When
Parameter: OFF|ON|0|1
Parameter Type: <boolean>
Default Value: OFF
Related Command: :CONFigure:CHPower
Front Panel Access: Shift-4 (Measure), Field Strength, On/Off
4-62
measurement result calculations. The <antenna> argument is a 1-based
index of the position of the desired antenna in the instrument's current
antenna list. The list can be displayed on the instrument by choosing
the "Antenna" submenu button in the "F Strength" menu. For example,
if the desired antenna were the 3rd item on the antenna listing then the
value of the <antenna> argument would be 3.
The query form of this command will return the index of the currently
selected antenna.
using :CONFigure:FSTRength, the state is automatically set to ON.
PN: 10580-00319 Rev. N
Spectrum Analyzer Commands
S412E PM

Advertisement

Table of Contents
loading

Table of Contents