LTE Commands
[:SENSe]:CELLID <char>
[:SENSe]:CELLID?
Title: Cell ID
Description: Sets the Cell ID value used when Sync Type is set to 'RS'.
Parameter: (the known Cell ID)
Parameter Type: <char>
Front Panel Access: Setup, Sync (RS), Cell ID
[:SENSe]:EMF:STATe OFF|ON|0|1
[:SENSe]:EMF:STATe?
Title: EMF State
Description: Switches EMF ON or OFF.
Parameter: OFF|ON|0|1
Parameter Type: <boolean>
Default Value: OFF
Front Panel Access: Measurements, Over-the-Air, EMF
[:SENSe]:EVM:MODe AUTO|PBCHonly
[:SENSe]:EVM:MODe?
Title: Set EVM Mode
Description: Sets/Returns the EVM Mode to either Auto or PBCH Only.
Parameter: AUTO|PBCHonly
Parameter Type: <char>
Default Value: AUTO
Front Panel Access: Setup, EVM Mode
S412E PM
The query form of this command returns a 0 or 1 when EMF state is
OFF or ON, respectively.
Note: EMF will turn ON only if the start and stop frequencies are
within the frequency range of the signal analyzer and isotropic antenna
used. The antenna must be connected.