14-4 :FETCh Subsystem
:FETCh:SIGAnalyzer?
Description: Returns the most recent DMR 2 Analyzer numerical measurement
14-10
results.
For firmware v1.13 and prior, data is returned as 14 comma-separated
values in the following order and format:
Received Power (dBm as float or Watts as long long int or Volts as
long long int)
Frequency Error (Hz as float)
Mod Fid (% as float)
BER (% as float)
Symbol Dev (Hz as float)
CC (hex)
Symbol Rate Error (Hz as float)
Source Address (as integer)
FLCO (as integer)
CSBKO (as integer)
FID (as integer)
Target ID (as integer)
Talk group ID (as integer)
Base Station ID (as integer)
For firmware v1.14 and later, data is returned as 13 comma-separated
values in the following order and format:
Received Power (dBm as float or Watts as long long int or Volts as
long long int)
Frequency Error (Hz as float)
Mod Fid (% as float)
BER (% as float)
Symbol Dev (Hz as float)
CC (hex)
Symbol Rate Error (Hz as float)
Source UID (as integer)
Target ID (as integer)
Talk Group ID (as integer)
FID (as integer)
Call Type (as char)
Base Station ID (as integer)
If there is no valid measurement data, the instrument will return "--" in
that field.