Anritsu LMR Master S412E Programming Manual page 598

An integrated, handheld multi-function land mobile radio test tool
Hide thumbs Also See for LMR Master S412E:
Table of Contents

Advertisement

16-13 [:SENSe] Subsystem
[:SENSe]:FREQuency:CENTer:AUTO OFF|ON|0|1
[:SENSe]:FREQuency:CENTer:AUTO?
Description: Sets auto scan on or off. When auto scan is turned on, the receiver
Cmd Parameters: OFF|ON|0|1
Query Parameters: NA
Range: OFF|ON|0|1
Default Value: OFF
Default Unit: NA
Example: To turn auto testing on:
Front Panel Access: Setup, Auto Scan
[:SENSe]:FREQuency:COUPling OFF|ON|0|1
[:SENSe]:FREQuency:COUPling?
Description: Turns on frequency coupling. When frequency coupling is on, the
Cmd Parameters: OFF|ON|0|1
Query Parameters: NA
Range: OFF|ON|0|1
Default Value: OFF
Default Unit: NA
Example: To turn Rx/Tx frequency coupling on:
Front Panel Access: Frequency, Rx/Tx Coupling
16-48
frequency will automatically be set to the frequency with the highest
power reading. Use [:SENSe]:FREQuency:CENTer? to retrieve the
current receiver frequency.
Changing the Rx frequency using the front panel or
[:SENSe]:FREQuency:CENTer <value> will turn Auto Scan off.
:FREQuency:CENTer:AUTO ON
Tx frequency cannot be set directly. The Rx Frequency and coupling
offset must be used to set the desired Tx frequency. The Tx frequency
will automatically trail the Rx frequency by the frequency coupling
offset every time the Rx frequency is set. Please note that turning on
frequency coupling will automatically move the Tx frequency to the
Rx frequency plus any frequency coupling offset. If the Rx frequency
and frequency coupling offset is at a setting where the Tx frequency will
be beyond the min/max limits, the instrument will not allow coupling to
be turned on. The query command returns the state of the frequency
coupling setting. A return value of 1 is ON, and a return value of 0 is
OFF.
:FREQuency:COUPling ON
PN: 10580-00319 Rev. N
NBFM Commands
S412E PM

Advertisement

Table of Contents
loading

Table of Contents