8-11 [:SENSe] Subsystem
[:SENSe]:PFail <test set>
[:SENSe]:PFail?
Title: PASS/FAIL Test Selection
Description: Selects the active test set to be used in subsequent PASS/FAIL
Parameter: <test set>
Related Command: :CONFigure PFail
Front Panel Access: Measurements, Pass/Fail Mode, Select Pass/Fail Test
[:SENSe]:POWer[:RF]:RANGe:AUTO OFF|ON|0|1
[:SENSe]:POWer[:RF]:RANGe:AUTO?
Title: Automatic Amplitude Range
Description: Sets the automatic amplitude range. Setting the value to ON or 1 will
Parameter: OFF|ON|0|1
Parameter Type: <boolean>
Default Value: ON
Related Command: :POWer[:RF]:RANGe
Front Panel Access: Amplitude, Auto Range
8-26
measurements. The <test set> value must correspond to a test set that
is defined in the test set list. To view the list on the instrument, go into
the "Measurement" menu, press the "Pass/Fail Mode" key, and then
press the "Select Pass/Fail Test" submenu. Alternatively, the list can be
retrieved remotely and viewed using the Anritsu Master Software
Tools. The <test set> argument is a 1-based index of the position of the
desired Pass/Fail test set in the instrument's current Pass/Fail test set
list. For example, if the desired Pass/Fail test is the 3rd item on the list
then the value of the <test set> argument would be 3.
When using the query form of the command, the return value is the
currently selected test set number. If there is not a valid test set
selected, the return value is "-1" (negative 1).
result in the amplitude range being coupled to the detected input signal
level. Setting the value to OFF or 0 will result in the input attenuation
being un-coupled from the input signal level. That is, changing the
input signal level will not change the amplitude range. When this
command is issued, the amplitude range itself will not change. The
default value is ON. That is, sending :SENS:POW:RANG:AUTO is
equivalent to sending :SENS:POW:RANG:AUTO ON.