Anritsu LMR Master S412E Programming Manual page 33

An integrated, handheld multi-function land mobile radio test tool
Hide thumbs Also See for LMR Master S412E:
Table of Contents

Advertisement

All Mode Commands
Related Command: :INSTrument:CATalog:FULL?
Front Panel
Access: Shift-9 (Mode) or Menu
:INSTrument[:SELect] <string>
:INSTrument[:SELect]?
Title: Select Mode by Name
Description: Sets the instrument mode based on the mode name that is specified by
Cmd Parameter: <string>
S412E PM
42 = PTC (PTC Analyzer mode)
43 = NBFM (NBFM Analyzer mode)
45 = TETRA (TETRA Analyzer mode)
6 = PM (Power Meter mode)
30 = AMFMPM (AM/FM/PM Analyzer mode)
15 = CS (Channel Scanner mode)
14 = IA (Interference Analyzer mode)
22 = CWSG (CW Signal Generator mode)
102 = VVM (Vector Voltmeter mode)
:INSTrument[:SELect]
:STATus:OPERation?
<string>. The query version returns the name of the current mode.
Use :INSTrument:CATalog:FULL? to get a list of available modes.
For example, for Vector Voltmeter, use "VVM".
SPA|HI_PM|WIMAX_D|WIMAX_E|MWVNA|LTE|P25|P25_2|NXDN|
DPMR|DMR_2|PTC|NBFM|TETRA|PM|AMFMPM|CS|IA|CWSG|VVM
SPA = Spectrum Analyzer mode
HI_PM = High Accuracy Power Meter mode
WIMAX_D = Fixed WiMAX mode
WIMAX_E = Mobile WiMAX mode
MWVNA = Microwave LMR Master mode
LTE = LTE Analyzer mode
P25 = P25 Analyzer mode
P25_2 = P25 Phase 2 Analyzer mode
NXDN = NXDN Analyzer mode
DPMR = dPMR Analyzer mode
DMR_2 = DMR 2 Analyzer mode
PN: 10580-00319 Rev. N
3-3 :INSTrument Subsystem
3-3

Advertisement

Table of Contents
loading