Mobile WiMAX Commands
[:SENSe]:POWer[:RF]:RANGe[:IMMediate]
Title: Amplitude Range
Description: Re-calculates amplitude range. Note that issuing this command will set
Related Command: :POWer[:RF]:RANGe:AUTO
Front Panel Access: Amplitude, Adjust Range
[:SENSe]:RF:SPECtrum:SPAN 5|10|20|30
[:SENSe]:RF:SPECtrum:SPAN?
Title: Spectrum View Span
Description: Sets the span for the Spectrum view. Setting the value to 5 will set the
Parameter: 5|10|20|30
Default Value: 10 MHz
Default Unit: MHz
Front Panel Access: Measurements, RF Measurements, Spectrum, Span
S412E PM
the automatic dynamic range OFF.
span for the Spectrum view to 5 MHz. Setting the value to 10 will set
the span for the Spectrum view to 10 MHz. Setting the value to 20 will
set the span for the Spectrum view to 20 MHz. Setting the value to 30
will set the span for the Spectrum view to 30 MHz.
PN: 10580-00319 Rev. N
8-11 [:SENSe] Subsystem