P25 Phase 2 Commands
11-7

:MEASure Subsystem

These commands take the instrument from its current state, enable the specified
measurement and put the instrument into single sweep mode. They correct any parameters
that are invalid given the new measurement state such that a valid measurement can take
place. Other settings may be changed; see the documentation of CONFigure for each
measurement. They then initiate the measurement. When the measurement is complete, they
return the result.
To make a measurement with settings other than the "default" measurement settings applied
by CONFigure, do the following:
• Send the appropriate CONFigure command to set the desired measurement.
• Modify the settings as required.
• Send the appropriate READ command to measure and return the result.
To get the current measurement data, use the appropriate FETCh command.
:MEASure:COVerage?
Description: Sets the active measurement to P25p2 Coverage, triggers a new
Cmd Parameters: NA
Query Parameters: NA
Range: NA
Default Value: NA
Default Unit: NA
Example: To measure P25p2 Coverage numerical data:
Front Panel Access: NA
S412E PM
measurement and returns the numerical results. It is a combination of
the commands :CONFigure:COVerage and :READ:COVerage?
Data is returned as 7 comma-separated values in the following order
and format:
RSSI (dBm as float)
BER (% as float)
Mod Fid (% as float)
Latitude (radian as float)
Longitude (radian as float)
UTC Date (month/day/year as char)
UTC Time (hour:minute:second as char)
If there is no valid measurement data, the instrument will return
"--,--,--,--,--,--,--".
:MEASure:COVerage?