4-14 [:SENSe] Subsystem
[:SENSe]:FREQuency:SIGStandard:NAMe <string>
[:SENSe]:FREQuency:SIGStandard:NAMe?
Title: Signal Standard
Description: Selects the desired signal standard from the list. The <string>
Parameter: <string>
Front Panel Access: Freq, Signal Standard
[:SENSe]:FREQuency:SPAN <freq>
[:SENSe]:FREQuency:SPAN?
Title: Frequency Span
Description: Sets the frequency span. Setting the value of <freq> to 0 Hz is the
Parameter: <freq>
Default Unit: Hz
[:SENSe]:FREQuency:SPAN:FULL
Title: Frequency Span – Full
Description: Sets the frequency span to full span. Note that changing the value of the
Front Panel Access: Span, Full Span
[:SENSe]:FREQuency:SPAN:PREVious
Title: Frequency Span – Last
Description: Sets the frequency span to the previous span value. Note that changing
Default Unit: Hz
Front Panel Access: Span, Last Span
4-60
argument is the name of the desired signal standard as displayed in the
instrument's current signal standard list. The list can be displayed on
the instrument by choosing the Signal Standard submenu button in the
Freq menu. The list can also be downloaded remotely and viewed using
Anritsu Master Software Tools. For example, if the desired Signal
Standard is P-GSM 900 - Uplink then the value of the <string>
argument would be "P-GSM 900 - Uplink".
The query form of this command will return the name of the currently
selected Signal Standard on the list.
equivalent of setting the span mode to zero span. Note that changing
the value of the frequency span will change the value of the coupled
parameters Start Frequency and Stop Frequency and may change the
Center Frequency.
frequency span will change the value of the coupled parameters, Start
Frequency and Stop Frequency and may change the Center Frequency.
the value of the frequency span will change the value of the coupled
parameters, Start Frequency and Stop Frequency and may change the
Center Frequency.