9-2 :CALCulate Subsystem

9-2
:CALCulate Subsystem
The commands in this subsystem process data that has been collected via the SENSe
subsystem.
:CALCulate:MARKer:AOFF
Title: Turn All Markers Off
Description: Turns off all markers in Channel Spectrum.
Front Panel Access: Marker, Markers Off
:CALCulate:MARKer1:DELTa:X <x1 parameter>
:CALCulate:MARKer1:DELTa:X?
Title: Delta Marker 1 X Value
Description: Sets/Queries the relative location of the delta marker from the reference
Parameter: <x1 parameter>
Default Unit: Hz
Related Command: :CALCulate:MARKer1:X
Front Panel Access: Marker, Marker Select (M1), Marker State (Delta), (Use arrow keys or
:CALCulate:MARKer1:DELTa:Y?
Title: Delta Marker 1 Read Y Value
Description: Reads the current absolute Y value for delta marker 1.
Default Unit: dBm
:CALCulate:MARKer1:MAXimum
Title: Set Marker 1 to Peak
Description: Moves marker 1 to peak position on data trace.
Parameter: NA
Front Panel Access: Marker, Marker Select (M1), Peak Search
9-2
marker on the x-axis.
Note: The query value might not always match the set value since the
instrument will round the set value based on the display pixel
resolution.
The x1 parameter is used to set the delta position.
For example, :CALC:MARK1:DELT:X 2 MHz will set the delta value to
2 MHz.
rotary knob.)