Co-Ds1 (Ds1 Co Trunk) - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:

CO-DS1 (DS1 CO Trunk)

Table 56. CO-DS1 (DS1 CO Trunk)
MO Name (in
Alarm Log)
CO-DS1
CO-DS1
CO-DS1
Note: For Avaya G700 systems you must consult local records for the location and
designation of the equipment rack where the G700 is mounted.
A Major alarm on a trunk indicates that alarms on these trunks are not downgraded by
**
the set options command and that at least 75 percent of the trunks in this trunk group are
alarmed.
The MM710 supports E1/T1 , and delivers the same functionality as the DEFINITY TN464 circuit
pack.
Many trunk problems are caused by incorrect settings of parameters on the trunk group
administration form. Settings must be compatible with the local environment and with parameter
settings on the far-end. Refer to "Chapter 12, Managing Trunks, in the Administrator's Guide for
Avaya MultiVantage
Application Notes section of that book shows the correct settings for administrable timers and other
parameters on a country-by-country basis.
A DS1 CO (central office) trunk provides a link for digitized voice or data communications between
the system and a central office switch. There are two types of DS1 interfaces:
• 24 DS0 channels on a 1.544 Mbps link
• 31 DS0 channels + 1 framing channel on a 2.048 Mbps link
• 32-channel mode is supported on TN464 Media Modules and on MM710 Media Modules.
The CO - DS1 maintenance object monitors and maintains a CO trunk port on a MM710 Interface
Media Module. See MG-DS1 in this chapter for more information about this Media Module. The DS1
Media Module supports low level CO trunk signaling interfaces for both ground-start and loop-start
trunks. This maintenance strategy covers the in-line errors log, initialization tests, periodic tests,
scheduled tests, demand tests, and alarm resolution.
Three trunk service states are specified by DS1 CO trunk maintenance:
Table 57. Trunk Service States
out-of-service
in-service
disconnect (ready-for-service)
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Alarm Level
Initial Command to Run*
MAJOR**
test trunk group# member# l
MINOR
test trunk group# member# l
WARNING
test trunk group# member#
Software, 555-233-506" for information on how to administer trunks. The
TM
The trunk is in a deactivated state and cannot be used
for either incoming or outgoing calls.
The trunk is in an activated state and can be used for
both incoming and outgoing calls.
The trunk is in an activated state but can only be used
for an incoming call.
CO-DS1 (DS1 CO Trunk)
Full Name of
MO
DS1 CO Trunk
DS1 CO Trunk
DS1 CO Trunk
115