ABB IRC5 Operating Manual page 551

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

133262, New index entry in file
Description
IPS has created in file: arg
a new index entry with value: arg
Recommended actions
133263, PPRU CAN Error
Description
PPRU unit: arg,
register 'arg' = arg
133264, PPRU Error
Description
PPRU unit: arg,
message = 'arg'
133265, SPI down: arg
Description
IPS on node arg has discovered an SPI-communication error.
arg
System will try to reconnect.
Recommended actions
1. Check serial cable to SPI board.
2. Check power cable to SPI board.
3. Check/replace SPI board.
133266, SPI up: arg
Description
SPI reconnected on node arg.
133267, Missing index entry in file
Description
IPS has tried to use a none existing index entry in file arg with
value arg.
Recommended actions
If this index entry is valid, it must be manually added to named
index file.
133268, arg: Failed to load brush table.
Description
IPS has tried to load brush table arg on the named device.
Recommended actions
1. Check other error messages for detailed explanation.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
133269, arg: Failed to set brush.
Description
IPS has tried to set brush number arg in brush table arg on the
named device.
Recommended actions
1. Check if brush table (or material) is selected.
2. Check if selected brush number exists in loaded brush table.
3. Check global brush table if brush number larger than 900.
133270, Failed to update IPS parameters
Description
IPS failed to update IPS parameter values after reconnect of
IPS agent connections. The update was initiated after the IPS
agents have been lost for any reason, typically caused by a
purge fault.
The system must be restarted to ensure all parameters are set
with correct values.
Consequences
IPS parameters may not have been updated with correct values.
Probable causes
IPS device or parameter may not exist or command is given
with an invalid value.
Recommended actions
1. Check if all IPS nodes are up and running.
2. Check IPS parameter files.
3. Restart system.
133271, IPS parameters updated
Description
IPS has updated parameter values after reconnect of IPS agent
connections, typically caused by a purge fault.
133280, Servo create error
Description
SDI board has discovered an error while
loading configuration.
Recommended actions
1. Check SDI configuration.
2. Check/replace SDI board.
3. Contact customer support.
133281, Servo meas. system error
Description
SDI board has discovered an error on the
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
Continues on next page
5.12 13 xxxx
Continued
551

Hide quick links:

Advertisement

Table of Contents
loading