ABB IRC5 Operating Manual page 119

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

Recommended actions
Make sure the LAN cable is working and correctly connected.
Make sure the DHCP server is activated. Set the LAN IP address
manually.
12514, Network interface initialization error
Description
The network interface arg could not be initialized.
Consequences
The interface will not be configured, and may not be used.
Probable causes
The network parameters may be wrong. Although unlikely, the
hardware may be faulty, requiring replacement.
Recommended actions
Make sure the network parameters for the interface at hand are
correct. Isolate the cause, by replacing the suspected hardware.
12515, Network interface IP addresses overlap
Description
The network IP address for 'arg' is overlapping with IP address
for 'arg'.
Consequences
The interface will not be configured, and may not be used.
Probable causes
The network IP address and subnet mask overlaps with other
IP address and subnet mask.
Recommended actions
Make sure the interface IP address and subnet mask are correct.
12610, Available RAM memory low
Description
The available amount of RAM memory is low. Total RAM
memory size: arg bytes. Free: arg bytes.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
Consequences
The system may run out of memory.
Recommended actions
It is recommended to restart the system.
12611, Available RAM memory very low
Description
The available amount of RAM memory is very low. Total RAM
memory size: arg bytes. Free: arg bytes.
Consequences
The system may run out of memory. Memory allocation for
non-production critical functionality will be rejected.
Recommended actions
It is highly recommended to restart the system.
12612, Available RAM memory too low
Description
The available amount of RAM memory is too low. Total RAM
memory size: arg bytes. Free: arg bytes.
Consequences
The system will enter System Failure State.
Recommended actions
Please restart the system.
12700, Missing time zone information
Description
No time zone information has been specified.
Recommended actions
Please use the FlexPendant or RobotStudio to set the time zone
for your location.
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log