5 Troubleshooting by event log
5.6 4 xxxx
Continued
41007, Item target buffer full
Description
Item target buffer full for item source arg.
41008, Conveyor I/O init error
Description
Error in the initialization of the I/O signal for item source arg,
for conveyor arg. I/O signal name arg.
41009, Conveyor does not exist
Description
Error for item source arg. The conveyor arg does not exist.
41010, No conveyor name given
Description
Error for item source arg. No conveyor name specified.
41011, Conveyor limits error
Description
Error for item source arg, conveyor arg. The limits are
incorrectly specified.
41012, Conveyor data are defined late
Description
Error for item source arg, conveyor arg. The ItmSrcCnvDat
instruction must be called before the ItmSrcFlush instruction.
41050, Profile not activated
Description
Profile record not ready.
Consequences
Profile data not activated.
Probable causes
Try to activate recorded profile too early.
Recommended actions
Instruction RecordProfile must be called before ActivateProfile.
41051, Recorded profile not stored
Description
No valid profile data to store.
Consequences
Nothing stored.
Continues on next page
262
Probable causes
Try to store a recorded profile not existing or not activated.
Recommended actions
Instruction ActivateProfile must be called before StoreProfile.
41052, Can't use this profile data file
Description
File not found or data not valid.
Consequences
Profile not used.
Probable causes
File not found or data not valid.
Recommended actions
Check file directory and name and profile data.
41100, Too Many Corrections
Description
Task: arg.
Max 5 correction descriptors are allowed to be connected.
Program ref: arg.
Recommended actions
Check number of connected descriptors.
Recovery: arg.
41101, Correction Not Connected
Description
Task: arg.
Cannot write to correction descriptor.
Program ref: arg.
Recommended actions
Check that the current correction descriptor is connected.
Recovery: arg.
41102, No Corrections Connected
Description
Task: arg.
Correction unable to be read.
Program ref: arg.
Probable causes
No correction descriptor connected.
Recommended actions
Check if any correction generator is connected.
Recovery: arg.