5 Troubleshooting by event log
5.8 7 xxxx
Continued
71502, PROFINET configuration mismatch
Description
The I/O device arg reported a different slot configuration
compared with the configuration for this I/O device in the
PROFINET configuration file arg.
First slot mismatch reported on slot arg.
arg slot mismatches found.
Consequences
Some I/O signals might not be possible to use.
Probable causes
The module type used in slot arg may be of wrong type or of a
different version compared to the actual hardware on the I/O
device.
Recommended actions
Update the PROFINET configuration file arg.Check the I/O
device hardware.
71503, PROFINET station name error
Description
The network system parameter Station Name on the arg network
contains one or more illegal characters. The character at
position arg is not allowed.
Consequences
The arg network is not possible to use.
Recommended actions
Change the Station Name system parameter to an allowed
string.
71504, File size exceeds max file size
Description
Unable to copy file data to the controller. The file arg is too
large.
File size: arg.
Max file size: arg.
Probable causes
The file size is larger than the allowed file size.
Recommended actions
Check the FTP client configuration and increase the system
parameter MaxFileSize to be able to transfer the file to the
controller.
Continues on next page
392
71505, Device command syntax error
Description
Could not send device command to I/O device arg because
there is a syntax error in the command path string.
Device command name arg.
The syntax error: Missing comma.
Consequences
The device command was not sent.
Recommended actions
Correct the device command path string.
71506, Device command syntax error
Description
Could not send device command to I/O device arg because
there is a syntax error in the command path string.
Device command name arg.
The syntax error: Bad path size specified.
Consequences
The device command was not sent.
Recommended actions
Correct the device command path string.
71507, Device command syntax error
Description
Could not send device command to I/O device arg because
there is a syntax error in the command path string.
Device command name arg.
The syntax error: Incorrect path size.
Consequences
The device command was not sent.
Recommended actions
Correct the device command path string.
71508, Device command syntax error
Description
Could not send device command to I/O device arg because
there is a syntax error in the command path string.
Device command name arg.
The syntax error: Bad data type.
Consequences
The device command was not sent.
Recommended actions
Correct the device command path string.
© Copyright 2005-2018 ABB. All rights reserved.