5 Troubleshooting by event log
5.8 7 xxxx
Continued
Recommended actions
Correct the operator.
71185, Duplicate name
Description
The I/O configuration is invalid.
The identifier arg has already been used as the name of another
configuration instance.
The following configuration instances must have unique names:
Industrial Networks I/O Devices Device Trust Levels I/O Signals
Commands Access Levels Signal Safe Levels Cross
Connections Routes
Recommended actions
Rename one of the configuration instances in I/O configuration.
Restart the controller.
71193, Invalid physical I/O mapping
Description
I/O mapping error on I/O device arg.
The I/O device uses an input size of arg bits, the controller can
handle maximum arg bits.
The I/O device uses an output size of arg bits, the controller
can handle maximum arg bits.
Recommended actions
Check configuration for the physical I/O device.
71196, Invalid encoding type
Description
The I/O configuration for I/O signal arg is invalid.
The encoding type arg is not valid for signal type arg.
Valid encoding types are: UNSIGNED TWO_COMP This I/O
signal has been rejected.
Recommended actions
Correct the encoding type for the I/O signal.
71201, Unknown network
Description
The I/O configuration is invalid.
The network arg cannot be found in the system.
Installed Industrial Networks are: arg arg arg arg.
Consequences
This network has been rejected, and no functions depending
on it will work.
Continues on next page
372
Recommended actions
Make sure the system has been configured with the desired
network. Make sure the network option at hand is installed.
Check the I/O configuration for network.
71205, Could not mount directory
Description
Mounting directory arg on the computer arg failed.
Protocol: arg.
Recommended actions
Check the FTP server setup. Check the FTP client configuration.
Check communication hardware, cabling.
71220, No PROFIBUS option has been installed
Description
A PROFIBUS board has been fitted, but no PROFIBUS option
has been installed.
Consequences
No communication on the PROFIBUS network is possible. There
may be consequential errors from configuring the PROFIBUS
network when no such option has been installed.
Probable causes
An attempt may have been made to add the PROFIBUS
functionality, without installing the option correctly.
Recommended actions
If the PROFIBUS option is required: configure a new system
with this option, and install the system. If the PROFIBUS option
is not required: configure a new system without this option, and
install the system.
71221, PROFIBUS firmware file not found
Description
The PROFIBUS firmware file was not found or not readable.
The board firmware may be out of date.
Recommended actions
Reinstall the system.
71222, PROFIBUS configuration file not found
Description
The binary PROFIBUS configuration file was not found. File:
arg. Path: arg.
Recommended actions
Make sure the file exists. Change the path in the I/O
configuration.