5 Troubleshooting by event log
5.8 7 xxxx
Continued
71485, Illegal subnet mask
Description
The subnet mask arg for the arg network is illegal. The allowed
subnet mask range is 255.255.255.xxx.
Consequences
The subnet mask on the arg network was not changed.
Recommended actions
Correct the subnet mask for the arg network.
71486, Illegal address for arg network
Description
The IP address arg for the arg network is illegal.
Consequences
The arg network cannot be used.
Recommended actions
Correct the address for the arg network.
71487, Illegal IP address for arg network
Description
The arg network address arg is reserved.
Consequences
No communication on the arg network is possible.
Probable causes
The specified address is on a subnet reserved by another
Ethernet port. Two Ethernet ports on the controller cannot be
on the same subnet.
Example:
arg port: 192.168.125.xxx
Service port: 192.168.125.xxx
Note:
The subnets within the range 192.168.125.xxx - 192.168.130.xxx
are predefined and cannot be used.
Recommended actions
Change the address to another subnet.
71488, Illegal gateway address for arg network
Description
The specified gateway address arg is not valid and cannot be
used.
Consequences
The gateway address is not changed.
Continues on next page
390
Probable causes
The specified gateway address might not be within the range
of the arg network subnet mask arg.
Recommended actions
Correct the gateway address in the arg network configuration.
71489, PROFINET internal device configuration
warning
Description
A PROFINET controller has established a connection with the
PROFINET internal device on the arg network. The connecting
PROFINET controller and the internal PROFINET device slot
configuration differs.
The internal PROFINET device is currently configured with the
following modules:
Slot 1: DI arg bytes.
Slot 2: DO arg bytes.
Consequences
Not all I/O signals will be possible to use.
Recommended actions
Reconfigure the connecting PROFINET controller to match the
internal PROFINET device. Reconfigure the internal PROFINET
device in the Robot controller to match the connecting
PROFINET controller.
71490, PROFINET I/O device configuration
warning
Description
The I/O device arg on the arg network is configured in the
PROFINET configuration file arg but not in the I/O configuration.
Recommended actions
Add the I/O device arg to the I/O configuration or remove the
I/O device from the PROFINET configuration file.
71491, PROFINET I/O device configuration
missing
Description
The I/O device arg on the arg network is configured in the I/O
configuration but not in the PROFINET configuration file arg.
Consequences
No communication with I/O device arg is possible.
Recommended actions
Add the I/O device arg to the PROFINET configuration file or
remove the I/O device from the I/O configuration.
© Copyright 2005-2018 ABB. All rights reserved.
Operating manual - Troubleshooting IRC5