ABB IRC5 Operating Manual page 477

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

110622, Invalid plate thickness
Description
Task: arg
Invalid value of the plate thickness parameter in spotdata.
Allowed values are: 0 to max arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value
is changed.
Recommended actions
Change the value of the plate thickness parameter in spotdata
or check that the correct external data is used via the plate
thickness group input (GI).
110623, Invalid plate tolerance
Description
Task: arg
Invalid value of the plate tolerance parameter in spotdata.
Allowed values are: 0 to max arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value
is changed.
Recommended actions
Change the value of the plate tolerance parameter in spotdata
or check that the correct external data is used via the plate
tolerance group input (GI).
110624, Invalid program number
Description
Task: arg
Invalid value of the weld timer program number parameter in
spotdata.
Allowed values are: 0 to max arg.
Current value: arg.
Consequences
It will not be possible to run any spot instructions until this value
is changed.
Probable causes
The program number parameter in spotdata has an invalid
value.
Recommended actions
Change the value of the program number parameter in spotdata
or check that the correct value is used as targetid or spotid.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
110625, Invalid simulation type
Description
Task: arg
Invalid value of the simulation type parameter in simdata.
Allowed values are: 0 to arg.
Current value: arg.
Consequences
It will not be possible to run any spot instructions until this value
is changed.
Recommended actions
Change the value of the simulation type parameter in simdata
110626, Invalid tip force
Description
Task: arg
Invalid value of the tip force parameter in forcedata.
Allowed values are: 0 to arg.
Current value: arg.
Consequences
It will not be possible to run any spot instructions until this value
is changed.
Recommended actions
Change the value of the tip force parameter in forcedata.
110627, Invalid plate thickness
Description
Task: arg
Invalid value of the plate thickness parameter in forcedata.
Allowed values are: 0 to max arg mm.
Current value: arg mm.
Consequences
It will not be possible to run any spot instructions until this value
is changed.
Recommended actions
Change the value of the plate thickness parameter in forcedata.
110628, Invalid plate tolerance
Description
Task: arg
Invalid value of the plate tolerance parameter in forcedata.
Allowed values are: 0 to arg mm.
Current value: arg mm.
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
Continues on next page
5.10 11 xxxx
Continued
477

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents