5 Troubleshooting by event log
5.10 11 xxxx
Continued
Recommended actions
Turn off the mains power supply to reset the unit.
112432, Receiver buffer overflow
Description
The welding data unit does not manage to process information
from the other units sufficiently quickly.
Fault code: arg
Internal unit: arg
Recommended actions
Turn off the mains power supply to reset the unit.
112434, Incompatible weld data format
Description
I/O unit: arg
Error code: arg
Internal unit: arg
112435, Program error
Description
Something has prevented the processor from performing its
normal duties in the program in unit arg.
Fault code: arg
Internal unit: arg
Consequences
The program restarts automatically. The current welding process
will be stopped.
Recommended actions
Review the handling of welding programs during welding. If the
fault is repeated, send for a service technician.
112436, No wire
Description
I/O unit: arg
Error code: arg
Internal unit:arg
112437, Lost program data
Description
Program execution does not work in unit arg.
Fault code: arg
Internal unit: arg
Continues on next page
530
Recommended actions
Turn off the mains power supply to reset the unit. If the fault
persists, send for a service technician.
112438, No water flow
Description
I/O unit: arg
Error code: arg
Internal unit: arg
112439, Lost contact with TIG card
Description
I/O unit: arg
Error code: arg
Internal unit: arg
112441, No gas flow
Description
I/O unit: arg
Error code: arg
Internal unit:arg
112500, Weld Data Monitor
Description
The configuration is complete for arg
112501, WDM Configuration Error
Description
The configuration failed for arg
Consequences
Weld Data Monitor will be inoperable.
Recommended actions
Please review PROC settings to correct.
112502, WDM Alias IO Error
Description
The signals defined in the PROC are invalid.
Task: arg
Consequences
Weld Data Monitor will be inoperable.
Recommended actions
Please review PROC settings to correct.