5 Troubleshooting by event log
5.8 7 xxxx
Continued
Recommended actions
Recommended action is to double-check that the controller is
connected to the expected remote host and then update the
fingerprint in configuration.
71597, Invalid SFTP fingerprint configured
Description
Security Alert!
Attempting to mount device on remote host arg failed. The
fingerprint check failed.
Protocol: arg.
Configured fingerprint: arg.
Received fingerprint: arg.
Consequences
No mounting can be done until the fingerprint configured
matches the one received.
Probable causes
The remote host that the controller is attempting to mount on
may be pretending to be someone that it not. The remote host
may have changed public key.
Recommended actions
Double-check that the controller is attempting to mount on the
expected remote host and then update the configuration.
71598, Could not mount device
Description
Mounting device on remote host arg failed.
Protocol: arg.
Recommended actions
Check the configuration.
404
71599, Mount permission denied
Description
Permission was denied to mount device on remote host arg.
Protocol: arg.
Recommended actions
Check the username and password.
71600, Authentication not supported by remote
host
Description
User and password authentication is currently required when
mounting a device on a remote host using SFTP. Remote host:
arg.
Protocol: arg.
Recommended actions
Configure the server to support password identification or
replace it with one that does.
71601, Unable to identify remote server
Description
SFTP fingerprint is configured to verify that the remote SFTP
server is the expected one and to do so the server must support
host key hash algorithm MD5 or SHA1. The used SFTP server
at remote host arg does not support any of them.
Protocol: arg.
Recommended actions
Remove the usage of fingerprint in the configuration or replace
the SFTP server.