Recommended actions
Correct the device map.
71562, Signal transfer has a split devicemap
Description
The transfer signal arg has a split device map, which is not
allowed.
Consequences
The configuration has been rejected.
Recommended actions
Correct the device map.
71563, Signal on internal device with signal
transfer definition
Description
The signal arg is on an internal device and cannot have a
transfer definition on it.
Consequences
The configuration has been rejected.
Recommended actions
Correct the configuration.
71564, Signal on internal device with signal
transfer definition
Description
The signal arg is being transferred to/from a network that is not
PROFINET.
Consequences
The configuration has been rejected.
Recommended actions
Correct the configuration.
71565, Signal on internal device overlaps with
transfer signal
Description
The signal arg and the signal arg on an internal device overlap.
Consequences
The configuration has been rejected.
Recommended actions
Correct the configuration.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
71566, Signal has both transfer signal attributes
Description
The signal arg has both the TransferFromDevice and
TransferToDevice attribute.
Consequences
The configuration has been rejected.
Recommended actions
Correct the configuration.
71567, Signal transfer without offset
Description
The signal arg is being transferred to/from a device but is
missing the offset attribute.
Consequences
The configuration has been rejected.
Recommended actions
Correct the configuration.
71568, Signal transfer to/from undefined device
Description
The signal arg is being transferred to/from an undefined device
arg.
Consequences
The configuration has been rejected.
Recommended actions
Correct the configuration.
71569, Signal has offset but no transfer attribute
Description
The signal arg has a transfer offset set but no
TransferFromDevice/TransferToDevice attribute.
Consequences
The configuration has been rejected.
Recommended actions
Correct the configuration.
71570, Signal has transfer defined with wrong
offset
Description
The signal arg has a transfer defined but uses the wrong offset.
Consequences
The configuration has been rejected.
© Copyright 2005-2018 ABB. All rights reserved.