5 Troubleshooting by event log
5.12 13 xxxx
Continued
due to this error.
Recommended actions
1. Output for symbol not defined.
2. Output for symbol has wrong name.
3. Internal problem (memory etc..)
Try a restart.
132601, PIB contact lost
Description
Controller has lost connection with the Process Interface Board
(PIB).
Consequences
The system goes to status SYS_FAIL.
Probable causes
1. Broken ethernet cable between PIB and MC
2. High network load.
Recommended actions
Check main computer
PIB Ethernet cable.
Restart the controller
132602, Invalid signal path for signal arg
Description
The path arg is invalid for signal arg
Consequences
This signal will be disabled
Recommended actions
Check that the named device exist in IPS and there are no
conflicts. For numeric unit mapping on digital signals, please
note that IPS uses 1-indexing while EIO uses 0-indexing.
132603, Watchdog fault between PIB and MC
Description
Controller has discovered watchdog fault towards Process
Interface Board (PIB)
Consequences
The system goes to status SYS_FAIL.
Probable causes
1. Broken cable
2. High network load.
Recommended actions
If problem persists:
Check main computer
Continues on next page
544
Check ethernet cable between PIB and main computer.
Restart the controller
132604, Regained contact with PIB
Description
Controller has regained contact with the Process Interface
Board (PIB) after watchdog fault.
132999, Process error context
Description
arg, arg, arg, arg, arg
Probable causes
This message is associated with an IPS error and is used to
map the problem to TCP position for visualization purposes.
133000, IPS Cfg Error
Description
Cfg Error: arg
Error accessing IPS config file arg. This config file is stored on
one of the installed IPS nodes.
Recommended actions
1. Check IPS config file for errors.
2. Check if config file is stored on the correct IPS node.
133001, IPS Cfg Error
Description
Cfg Error: arg.
Error in IPS config file arg in line arg. This IPS config file is
located on one of the IPS nodes.
Recommended actions
1. Check in IPS config file for error in given line.
133002, IPS Cfg Error
Description
Syntax Error: arg.
Faulty argument: arg, in IPS config file arg in line arg. This IPS
config file is located on one of the IPS nodes.
Recommended actions
1. Check in IPS config file for error in given line.
133003, IPS Cfg Error
Description
Assertion error: arg.
© Copyright 2005-2018 ABB. All rights reserved.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA

Hide quick links:

Advertisement

Table of Contents
loading