41466, The Variables Are Equal
Description
Task: arg.
The argument FromRawData and ToRawData are equal.
Program ref: arg.
Recommended actions
Check and change the RAPID program.
41467, Value Error
Description
Task: arg.
Illegal value in argument arg.
Program ref: arg.
Recommended actions
Check and change the value. It must be an integer and in range
0 to 255.
41468, Value Error
Description
Task: arg.
Illegal value in argument arg.
Program ref: arg.
Recommended actions
Check and change the value. NoOfBytes must be an integer
and in range 1 to 1024, and not higher than RawData length.
41469, Value Error
Description
Task: arg.
Illegal value in argument arg.
Program ref: arg.
Recommended actions
Check the value. NoOfBytes must not be higher than RawData
length.
41470, Argument Error
Description
Task: arg.
Argument arg or arg not within range.
Program ref: arg.
Recommended actions
Check and change the value of the argument.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
41471, Instruction Error
Description
Task: arg.
You are not allowed to deactivate I/O device arg.
Program ref: arg.
Recommended actions
Recovery: arg.
41472, Instruction Error
Description
Task: arg.
There is no client e.g. a FlexPendant taking care of instruction.
Program ref: arg.
Recommended actions
Recovery: arg.
41473, System Access Error
Description
It was not possible to send data using SCWrite to external
computer. Failed to send variable arg.
41474, Value Error
Description
Task: arg.
Illegal value in argument arg.
Program ref: arg.
Recommended actions
Check the value: arg arg must be a positive integer.
41475, Wrong size of task list
Description
Task: arg.
The task list has wrong number of elements. It must not have
less than 1 or more than arg.
Program ref: arg.
Recommended actions
Check and change the number of arguments in the task list.
41476, Non-consistent task list
Description
Task: arg.
arg in the task list is not one of the tasks that are configured in
the system (max arg tasks can be configured).
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
Continues on next page
5.6 4 xxxx
Continued
271