ABB IRC5 Operating Manual page 376

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

5 Troubleshooting by event log
5.8 7 xxxx
Continued
is not required: configure a new system without this option, and
install the system.
71303, Invalid DeviceNet vendor id
Description
The vendor id read from DeviceNet I/O device arg doesn't match
value in I/O device configuration. Configuration: arg. Actual:
arg.
Consequences
It is not possible to access the I/O device or I/O signals on it.
Recommended actions
Change vendor id in I/O configuration. Check that the type of
I/O device is correct.
71304, Invalid DeviceNet device type
Description
The device type read from DeviceNet I/O device arg doesn't
match value in device I/O configuration. Configuration: arg
Actual: arg
Consequences
It is not possible to access the I/O device or I/O signals on it.
Recommended actions
Change device type in I/O configuration. Check that the type
of I/O device is correct. Check for a duplicate DeviceNet address
in the connected I/O units.
71305, Invalid DeviceNet product code
Description
The product code read from DeviceNet I/O device arg doesn't
match value in I/O device configuration. Configuration: arg
Actual: arg
Consequences
It is not possible to access the I/O device or I/O signals on it.
Recommended actions
Change product code in I/O configuration. Check that the type
of I/O device is correct. Check for a duplicate DeviceNet address
in the connected I/O units.
71306, DeviceNet unknown error
Description
An unknown error is reported from I/O device arg error code
arg.
Continues on next page
376
Recommended actions
Restart the controller. Report the problem to ABB.
71307, DeviceNet generic connection 1
Description
On DeviceNet I/O device arg connection 1 configuration is
generic.
Real values: Connection 1 type: arg. Connection 1 input size:
arg. Connection 1 output size: arg.
Recommended actions
Update your current I/O device configuration.
71308, DeviceNet generic connection 2
Description
On DeviceNet I/O device arg connection 2 configuration is
generic.
Real values: Connection 2 type: arg. Connection 2 input size:
arg. Connection 2 output size: arg.
Recommended actions
Update your current I/O device configuration.
71309, DeviceNet generic device identification
Description
On DeviceNet I/O device arg identity configuration is generic.
Real values: Vendor Id: arg. Product code: arg. Device type:
arg.
Recommended actions
Update your current I/O device configuration.
71310, DeviceNet I/O device connection error
Description
DeviceNet I/O device arg is occupied by another master.
Recommended actions
Check I/O configuration. Cycle power on I/O device.
71311, Unable to establish communication on
the DeviceNet network
Description
Unable to establish communication on the DeviceNet network
because no I/O devices are physically connected.
Recommended actions
Check cables and connectors. Connect I/O devices to network.
Restart the controller. Remove I/O devices on the DeviceNet
network from the I/O configuration.
© Copyright 2005-2018 ABB. All rights reserved.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents