ABB IRC5 Operating Manual page 383

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

No user-defined I/O device may be connected to the network
Local.
This I/O device has been rejected.
Recommended actions
Correct the I/O configuration.
71385, Request message resource exhausted
Description
Unable to handle more concurrent I/O requests.
Out of concurrent I/O request using delay, pulse, or timeout
argument.
Consequences
I/O request cannot be fulfilled.
Probable causes
Too many I/O instructions with pulse or delay argument.
Too many process instructions with pulse, delay or timeout.
Recommended actions
Reduce the number of concurrent I/O instructions with pulse
or delay argument. Reduce the number of concurrent process
instructions that use pulse, delay or timeout argument.
71390, The DeviceNet network has recovered
from bus off
Description
The DeviceNet network has recovered from bus off state.
71391, System Signal configuration
Description
There was an error during the configuration of the System I/O
Signal arg.
Consequences
The system will go to system failure state.
Probable causes
All errors during configuration of System I/O Signals are
considered fatal and the system will go to system failure state.
Recommended actions
Check the connection of the I/O device to which the System
Signal is connected. Check the configuration of the I/O device.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
71392, Invalid output size
Description
On DeviceNet I/O device arg the connection output size arg
does not match the I/O device. When using strobe connection
the only valid output sizes are 1 or -1.
Recommended actions
Change size in configuration. Check module. Use DN_Generic
device template.
71393, Error when allocating generic size
Description
Failed to allocate generic arg size (-1) on DeviceNet I/O device
arg.
Probable causes
The DeviceNet I/O device arg cannot be configured with a
generic arg size (-1).
Recommended actions
Update your current unit type configuration with new arg size.
Use DN_Generic device template.
71394, Invalid physical communication channel
Description
The communication channel arg is out of range.
Consequences
The communication channel arg is unavailable.
Probable causes
Adapter board DSQC 1003 not installed or the communication
channel arg is out of range.
Recommended actions
Check the allowed minimum and maximum of connectors.
Check hardware required.
71395, No transport protocol
Description
The transport protocol arg for channel arg is missing.
Consequences
The transport instance arg is unavailable.
Probable causes
The option holding the transport protocol arg is not installed or
the protocol name is faulty.
Recommended actions
Install missing option. Change the transport protocol name.
© Copyright 2005-2018 ABB. All rights reserved.