Recommended actions
Change the input/output size to a value greater value than zero.
71405, Duplicate device mapping
Description
The I/O signal arg has overlapping bit(s) in the device map with
the I/O signal arg.
Consequences
This I/O signal has been rejected, and no functions depending
on it will work.
Recommended actions
Correct the device mapping for the overlapping I/O signals in
the I/O configuration.
71406, Communication established on DeviceNet
network
Description
The DeviceNet network has established communication.
71407, Route interface not found
Description
The route interface arg for network arg is not found in the
system.
Consequences
The route is not available. Messages to I/O devices connected
to the network arg will not forwarded.
Probable causes
The network arg not defined.
Recommended actions
Change the network identifier.
71408, Route port number out of range
Description
The given port number arg of route arg is outside its range.
Consequences
The route is not available. Messages to I/O devices connected
to the network arg will not be forwarded.
Probable causes
The number arg is outside its range.
Recommended actions
Change port number.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
71409, Not able to add a port to arg
Description
Not able to define port arg of route arg due to lack of resources.
Consequences
The route is not available. Messages to I/O devices connected
to port arg are not forwarded.
Probable causes
The network arg doesn't support this many ports.
Recommended actions
When possible reduce the number of ports or report the problem
to ABB.
71410, CIP route option not installed
Description
The CIP route option is not enabled since it was not selected
at system creation.
Consequences
Any CIP route definitions will be omitted.
Probable causes
The CIP route option is not installed in the system.
Recommended actions
Create and install a system with the CIP route option.
71411, Out of route resources
Description
Not able to add anymore routes due to no more route resources
in the system.
Consequences
Route arg will not be added to the system.
Probable causes
Too many routes have been defined. The system only allows
arg routes.
Recommended actions
Reduce the number of routes.
71412, The DeviceNet network has regained the
bus power
Description
The DeviceNet network has regained the 24 V bus power.