5 Troubleshooting by event log
5.12 13 xxxx
Continued
133013, IPS License Error
Description
Protocol error in communication towards license server.
Could not obtain option: arg
Reference: arg
Recommended actions
1. Contact customer support.
133014, IPS License Error
Description
Communication fault. License server has been found, but
communication is lost.
Could not obtain option: arg
Reference: arg
Recommended actions
1. Check communication towards license server.
133200, arg:Trig error
Description
IPS has discovered an
impossible trig time error.
This situation may occur if trig-events
are programmed too close each other in
e.g. a cleaning sequence.
Recommended actions
1. Check if events for named device
are programmed too close each other.
2. Check compensation delays for
named device.
133201, arg:Locked
Description
The named device is locked by IPS.
Can't set a value to this
device when locked, and there is no
direct access to it.
Recommended actions
1. Check if system tries to run named
device, when it is already locked
(connected) to another device.
133202, arg:Disabled
Description
Impossible to set a command value to
Continues on next page
546
named device when it is disabled.
When a device is disabled, it is not
possible to operate it.
Recommended actions
1. Enable named device and set a new
command to it.
2. Check if IPS config is set up to
disable the named device.
133203, arg:Disconn.
Description
The resource(s) for named device is
disconnected and named device is not
operational. The connect signal for
the device is set to 0.
Recommended actions
1. Set the connect signal for the
named device to 1.
2. Check if the system sets the connect
signal to 0 in some special cases.
133204, arg:Not ready
Description
Can't set value: Named device is not
ready and is halted by some supervision
functions or it have a general problem.
Recommended actions
1. Check if IPS is setup with any
supervision functions for named device.
2. Check if named device have any
problem, fix the problem and retry.
133205, arg:Sprv. alarm
Description
Can't set value:An alarm that is
supervising named device is active.
One of the installed alarms prevents the
named device from being operational.
Recommended actions
1. Check for supervision alarms that
sets named device in a not ready state.
2. Fix the actual alarm state.