Advertisement

5 Troubleshooting by event log
5.6 4 xxxx
Continued
Recommended actions
Installed objects must have names that are unique. Rename
the object or change the conflicting name.
40252, Limit error
Description
Task arg: Error arg when creating sdb entry for arg.
Recommended actions
An error occurred when the persistent was to be inserted into
the shared database. Probably the database is full.
40253, Type definition error
Description
Task arg: Alias arg of alias arg not allowed.
Recommended actions
It is not possible to define an alias type equal to another alias
type. Instead, define two alias types equal to the same atomic
or record type.
40254, Symbol definition error
Description
Task arg: 'ANYTYPE#' parameter arg cannot be dimensioned.
Recommended actions
Remove the dimension specification. 'ANYTYPE#' includes
array types.
40255, Symbol definition error
Description
Task arg: 'ANYTYPE#' only allowed for parameter (not for arg).
Recommended actions
Use another type.
40256, Parameter error
Description
Task arg: 'alt' must not be set for first optional parameter arg
in alternatives list.
Recommended actions
Make sure that only the second and following in each list of
excluding optional parameters are marked as alternatives.
40257, Parameter error
Description
Task arg: REF mode parameter arg cannot be dimensioned.
Continues on next page
230
Recommended actions
Remove the array dimension specification, or change the mode
of the parameter.
40258, Parameter error
Description
Task arg: 'switch' parameter arg cannot be dimensioned.
Recommended actions
Remove the array dimension specification, or change the data
type of the parameter.
40259, Parameter error
Description
Task arg: 'switch' parameter arg must have transfer mode IN
(specified value arg).
Recommended actions
Remove the parameter transfer mode specifier. If IN transfer
mode is not sufficient, change the data type of the parameter.
40260, Symbol definition error
Description
Task arg: 'switch' only allowed for optional parameter (not for
arg).
Recommended actions
Change the parameter into an optional parameter, or change
the data type of the parameter. If the object is not a parameter,
change the data type.
40261, Type definition error
Description
Task arg: Value type class for arg must be one of
REAL_SYMVALTYP_VAL, _SEMIVAL, _NONVAL or _NONE
(specified value arg).
Recommended actions
Change the value type class.
40262, Data declaration error
Description
Task arg: Too many array dimensions for arg (specified value
arg).
Recommended actions
An array may have at most 3 dimensions.
© Copyright 2005-2018 ABB. All rights reserved.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA