120001, Out of memory in cfg
Description
There is not enough memory in the cfg database for this
operation.
Consequences
The configuration file will not be installed.
Recommended actions
Try to use the option: delete existing parameters before loading
when loading the configuration file. This will delete all previous
configuration settings for the domain. Increase the size of the
configuration database.
120002, Instance cannot be saved
Description
Not allowed to overwrite instance in line arg of file arg.
Consequences
The instance may be write protected and the configuration in
file will not be installed.
Probable causes
Recommended actions
You are not allowed to change the instance.
120003, Wrong cfg domain version
Description
The cfg domain version is wrong in file arg. This version of
RobotWare is made for reading domain arg with version arg.
Consequences
The configuration in file might not be installed correctly.
Probable causes
Recommended actions
Migrate or edit the configuration file and update the version in
the header of the file.
120004, Line too long
Description
Line arg in file arg contains arg characters, which is more than
the allowed arg.
Consequences
The configuration in file will not be installed.
Probable causes
Continues on next page
538
Recommended actions
Re-edit the configuration file and reduce the number of
characters, e.g. by splitting the instance into several lines. End
each line, except the last one, with a trailing backslash "\" to
achieve this.
120005, Attribute value out of allowed range
Description
Attribute 'arg' on line arg in file arg is out of the allowed range.
The allowed range is < arg> - < arg>.
Consequences
The configuration in file will not be installed.
Probable causes
Recommended actions
Re-edit the configuration file and change the value on the
attribute to fit inside the allowed range.
120006, Instance name occupied
Description
Instance in line arg in file arg is already occupied.
Consequences
The configuration in file will not be installed.
Probable causes
Recommended actions
Re-edit the configuration file and change the instance name to
add it to the file OR Use the "Replace" mode to overwrite the
instance previously using the name. This may be selected when
loading the configuration file using RobotStudio, and the
procedure is detailed in the RobotStudio Manual.
120007, Unknown input in cfg file
Description
The name or the value of attribute 'arg' in line arg in file arg is
not recognized.
Consequences
The configuration in file will not be installed.
Probable causes
The configuration file contains invalid input.
Recommended actions
Re-edit the configuration file.