ABB IRC5 Operating Manual page 482

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

5 Troubleshooting by event log
5.10 11 xxxx
Continued
110653, Unexpected tip size moveable tip
Description
Task: arg
New moveable tip with unexpected size, the size of the tips
exceeds the configured tip change supervision value.
Difference between new and old (worn) tips): arg mm.
Tip change tolerance: arg to arg mm.
Current gun: arg
Probable causes
1. Tips with unexpected size was mounted on the gun.
2. The size exceeds the maximum allowed value defined in the
tip change supervision configuration data.
Configuration/Process/Spot Gun Equipment/Tip change
supervision value.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the maximum allowed supervision value is big
enough.
110654, Unexpected tip size fixed tip
Description
Task: arg
New fixed tip with unexpected size, the size of the tips exceeds
the tip change supervision value.
Difference between actual tip and reference tip: arg mm.
Tip change tolerance: arg to arg mm.
Current gun: arg
Probable causes
1. Tips with unexpected size was mounted on the gun.
2. The size exceeds the maximum allowed value defined in the
tip change supervision configuration data.
Configuration/Process/Spot Gun Equipment/Tip change
supervision value.
Recommended actions
1. Check that the correct tips are mounted on the gun.
2. Check that the maximum allowed supervision value is big
enough.
110655, Tip wear out of range moveable tip
Description
Task: arg
Tip wear out of range, the tip wear exceeds the configured tip
wear supervision value.
Actual tip wear (moveable tip): arg mm.
Tip wear tolerance: arg to arg mm.
Continues on next page
482
Current gun: arg
Probable causes
The current tip wear exceeds the maximum allowed value
defined in the tip wear supervision configuration data.
Configuration/Process/Spot Gun Equipment/Tip wear
supervision value.
Recommended actions
Check that the maximum allowed supervision value is big
enough.
110656, Tip wear out of range fixed tip
Description
Task: arg
Tip wear out of range, the tip wear exceeds the configured tip
wear supervision value.
Actual tip wear (fixed tip): argmm.
Tip wear tolerance: arg to arg mm.
Current gun: arg
Probable causes
The current tip wear exceeds the maximum allowed value
defined in the tip wear supervision configuration data.
Configuration/Process/Spot Gun Equipment/Tip wear
supervision value.
Recommended actions
Check that the maximum allowed supervision value is big
enough.
110657, Independent mode error
Description
Task: arg
It is not possible to use independent gun mode in Spot
instructions when software equalizing is activated.
Current gun: arg
Consequences
It will not be possible to run any spot instruction until the
independent mode is deactivated.
Probable causes
The independent gun mode is activated.
Recommended actions
Reset the independent mode with the instruction
'IndGunMoveReset'.
© Copyright 2005-2018 ABB. All rights reserved.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents