ABB IRC5 Operating Manual page 371

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

Recommended actions
Restart the controller.
71158, Address out of range
Description
The I/O configuration is invalid.
The address of I/O device arg is invalid (out of range).
This I/O device has been rejected.
Recommended actions
Change the address. Check the address syntax.
71163, I/O signal on internal I/O device
Description
The I/O configuration is invalid.
The user-defined I/O signal arg must not be connected to the
internal I/O device arg.
User defined I/O signals are not allowed to be connected to
internal I/O devices.
This I/O signal has been rejected.
Recommended actions
Connect the I/O signal to another I/O device.
71164, Internal I/O signal in cross connection
Description
The I/O configuration of cross connection arg is invalid.
The Actor arg arg is a user-defined I/O signal whereas the
resultant I/O signal arg is an internal I/O signal.
It is not allowed to define cross connections where user-defined
I/O signals affect internal I/O signals.
Consequences
The cross connection has been rejected, and no functions
depending on it will work.
Recommended actions
Correct the cross connection so that there are no internal I/O
signals in the resultant expression.
71165, FTP server went down
Description
The connection to a non-trusted FTP server has been lost.
IP address: arg.
Recommended actions
Check cable and FTP server settings.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
71166, FTP server went down
Description
The connection to a trusted FTP server has been lost.
IP address: arg.
Recommended actions
Check cable and FTP server settings.
71167, Wrong transmission protocol
Description
No matching transmission protocol was found in the
communication configuration.
Recommended actions
Change the transmission protocol.
71169, Ethernet not installed
Description
The option Ethernet Services with FTP is not installed on this
system.
Recommended actions
Restart the controller and install the Ethernet Services with FTP
option.
71182, I/O signal undefined
Description
The I/O configuration of cross connection arg is invalid.
The parameter Resultant contains a reference to an undefined
I/O signal arg.
Consequences
The cross connection has been rejected, and no functions
depending on it will work.
Recommended actions
Correct the cross connection so that the resultant I/O signal
refers to an existing I/O signal.
71183, Cross connection with invalid operator
Description
The I/O configuration of cross connection arg is invalid.
The parameter Operator arg contains an invalid/unknown
operator arg.
Valid values for the logical operator are: AND OR
Consequences
The cross connection has been rejected, and no functions
depending on it will work.
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
Continues on next page
5.8 7 xxxx
Continued
371