5 Troubleshooting by event log
5.8 7 xxxx
Continued
71517, An attribute is changed for an EtherNet/IP
adapter
Description
The attribute arg is changed to "arg" for the adapter arg.
71519, Too many PROFINET Networks are
configured
Description
Too many PROFINET Controller/Device Industrial Networks
are configured. It is only possible to have one network for
PROFINET Controller/Device.
Recommended actions
Remove all but one of the PROFINET Controller/Device
Industrial Networks from the configuration. Restart the
controller.
71520, Input data invalid
Description
The I/O device arg indicates input data invalid from slotarg.
Consequences
The input data is discarded.
Probable causes
Internal error in the I/O device.
71521, Output data not processed
Description
The I/O device arg indicates output data to slot arg cannot be
processed.
Consequences
The output data is discarded by the I/O device.
Probable causes
Internal error in the I/O device.
71522, Ethernet port occupied by another client
Description
The specified Ethernet port for EtherNet/IP network is occupied
by another client.
Consequences
No communication on the EtherNet/IP network is possible.
Probable causes
A MultiMove system is installed and occupies the specified
Ethernet port.
Continues on next page
394
Recommended actions
Select another Ethernet port by changing the connector ID for
the EtherNet/IP network.
71524, PROFINET I/O device unknown alarm
Description
The I/O device arg has reported an unknown alarm in slot arg
Use I/O device specific documentation for explanation on the
alarm code.
Alarm code: arg.
71525, PROFINET I/O device diagnostics
Description
The I/O device arg has reported diagnostic data in slot arg.
Use I/O device specific documentation for more explanation on
the diagnostic data.
arg.
71526, PROFINET I/O device unknown alarm
Description
The I/O device arg has reported an unknown alarm in slot arg
Use I/O device specific documentation for explanation on the
alarm code.
Alarm code: arg.
71527, EtherNet/IP adapter state conflict
Description
The current state of the adapter arg prevents communication
from being established or the execution of a specific service.
This is an adapter specific behavior documented by the vendor.
Consequences
No communication with the adapter arg is possible as long as
the adapter is in this state.
Recommended actions
Verify the current state of the adapter arg.If the state is error,
check the I/O configuration or hardware setup of the adapter
and consult the vendor documentation. If the state is running,
the I/O device was earlier temporarily busy during
communication attempt but has now recovered, no further
actions are necessary.
71528, EtherNet/IP general failure
Description
Not able to connect to the adapter arg.
© Copyright 2005-2018 ABB. All rights reserved.