5 Troubleshooting by event log
5.8 7 xxxx
Continued
71396, No transmission protocol
Description
The transport protocol arg is missing or the name of the
transport protocol is faulty for arg.
Consequences
The application protocol instance arg is unavailable.
Probable causes
The option holding the transport is not installed or the
application name is faulty.
Recommended actions
Install the option. Change the name of the transport in the
configuration.
71397, No application protocol
Description
The application protocol arg is missing or the name is faulty.
Consequences
The application instance arg is unavailable.
Probable causes
The option holding the application protocol is not installed or
the protocol name is faulty.
Recommended actions
Install the option. Change the name of the application protocol.
71398, Communication error from bosv24
Description
No response from the serial line.
Recommended actions
Check the device or connection.
71399, Communication error from bosv24
Description
Not possible to deliver the received message.
Recommended actions
Check the communication flow.
71400, Communication error from bosv24
Description
The response from the device has an invalid frame sequence.
Recommended actions
Check for noise on the serial line.
Continues on next page
384
71401, No option exists for the arg Anybus
module.
Description
An arg Anybus module has been found, but no option has been
installed.
Consequences
No communication on arg Anybus module is possible. There
may be consequential errors from configuring when no such
option has been installed.
Probable causes
An attempt may have been made to add the arg Anybus module
functionality, without installing the option correctly.
Recommended actions
If the arg Anybus module option is required: configure a new
system with this option, and install the system.
71402, Duplicate address on the arg network.
Description
The arg network address is duplicated on the network.
Conflicting address arg.
Consequences
No communication on the arg network is possible.
Recommended actions
Change the address on the conflicting adapter (or physically
disconnect the adapter) or change the address for the arg
network.Restart the controller.
71403, The interval time is invalid
Description
For the DeviceNet device arg the connection arg interval time
is invalid.
Probable causes
The interval time has a lower value than the production inhibit
time.
Recommended actions
Change the connection arg interval time to be higher than the
production inhibit time for the DeviceNet device arg in the I/O
configuration.
71404, Invalid input/output size
Description
The I/O device arg has an invalid value (zero) for the input or
output size.
© Copyright 2005-2018 ABB. All rights reserved.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA