5 Troubleshooting by event log
5.8 7 xxxx
Continued
71350, Invalid network
Description
The I/O configuration is invalid.
The device predefined type arg has an invalid/unknown type
of network arg.
Installed valid Industrial Networks are:arg arg arg.
Consequences
This device predefined type has been rejected, and no functions
depending on it will work.
Recommended actions
Correct the network for the device predefined type.
71351, Invalid connection 1 type
Description
The I/O configuration is invalid.
The unit type arg has an invalid/unknown type for connection
1 arg.
The type for connection 1 must be one of the following: POLLED
STROBE COS CYCLIC COS_ACKSUP CYCLIC_ACKSUP This
unit type has been rejected.
Recommended actions
Correct the connection 1 type of the unit type.
71352, Invalid connection 2 type
Description
The I/O configuration is invalid.
The unit type arg has an invalid/unknown type for connection
2 arg.
The type for connection 2 must either be omitted or one of the
following: POLLED STROBE COS CYCLIC COS_ACKSUP
CYCLIC_ACKSUP This unit type has been rejected.
Recommended actions
Correct the connection 2 type of the unit type.
71354, I/O device without reference to network
Description
The I/O configuration is invalid.
No reference to a network is defined for the I/O device arg.
This I/O device has been rejected.
Recommended actions
Define a network reference for the I/O device.
Continues on next page
380
71355, Invalid Device Trust Level
Description
The I/O configuration is invalid.
I/O device arg has an invalid/unknown Device Trust Level: arg.
Installed valid Device Trust Levels are:arg.
Consequences
This I/O device has been rejected, and no functions depending
on it will work.
Recommended actions
Correct the Device Trust Level for the I/O device.
71356, Bus type mismatch
Description
The I/O configuration is invalid.
Device arg refers to a network and a unit type with different bus
types.
This I/O device has been rejected.
Recommended actions
Check that the I/O device is connected to the correct network
and that the bus type of that network is correct. Check that the
I/O device refers to the correct unit type and that the bus type
of that unit type is correct.
71357, Duplicated I/O devices on network Local
Description
The I/O configuration for I/O device arg is invalid.
There is already another user-defined I/O device connected to
the network Local.
Only one user-defined I/O device may be connected to the
network Local.
This I/O device has been rejected.
Recommended actions
Correct the I/O configuration.
71361, Cross connection with non-digital
resultant I/O signal
Description
The I/O configuration of cross connection arg is invalid.
The parameter Resultant refer to an I/O signal arg, that is not
digital.
Only digital I/O signals can be cross connected.
Consequences
The cross connection has been rejected, and no functions
depending on it will work.