ABB IRC5 Operating Manual page 533

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

Consequences
Weld Data Monitor will be inoperable.
Recommended actions
Restarting the controller and starting from the main may resolve
the problem for the next learning cycle. Deleting the file may
also resolve the problem.
112521, WDM File Access Error
Description
Could not close a binary data file.
Task: arg
Consequences
Weld Data Monitor may be inoperable.
Recommended actions
Restarting the controller and starting from the main may resolve
the problem for the next learning cycle. Deleting the file may
also resolve the problem.
112522, WDM File Access Error
Description
Could not seal the binary data file described below.
File: arg
Task: arg
Consequences
Weld Data Monitor will be inoperable.
Recommended actions
Restarting the controller and starting from the main may resolve
the problem for the next learning cycle. Deleting the file may
also resolve the problem.
112523, WDM Sample Size Error
Description
The number of points stored in the last weld seam does not
match the number stored in the existing signature file.
Seam Name: arg
Task: arg
Measured samples: arg
Signature samples: arg
Consequences
Weld Data Monitor will be unable to evaluate the data from this
seam.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
112524, WDM Weld End Error
Description
An unspecified error occurred at the end of the seam.
Task: arg
Consequences
Weld Data Monitor may be inoperable.
Recommended actions
Please contact your ABB representative.
112525, WDM Weld Start Error
Description
An unspecified error occurred at the start of the seam.
Task: arg
Consequences
Weld Data Monitor may be inoperable.
Recommended actions
Please contact your ABB representative.
112526, WDM Learning Started
Description
No previously stored signature exists for arg in task arg.
Learning will begin now.
Learning cycles required: arg
112527, WDM Text Resource Error
Description
Text Resource Error.
Weld Data Monitor could not access text.
Index: arg
File: arg
Task: arg
Recommended actions
Please contact your ABB representative.
112528, WDM Minor Infraction
Description
A minor arg infraction has occurred in seam arg.
Measured value: arg
Maximum limit: arg
Minimum limit: arg
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
Continues on next page
5.10 11 xxxx
Continued
533

Hide quick links:

Advertisement

Table of Contents
loading