Recommended actions
Re-establish the connection with the I/O device. To make it
possible to restart the program move PP to a safe restart
position.
41427, Argument Error
Description
Task arg: The delaytime has to be positive.
Program ref: arg.
Recommended actions
Change the value of delaytime.
41428, Axis Error
Description
Task: arg.
The single axis is not init correctly. The sensor is not activated.
Program ref: arg.
41429, Axis Error
Description
Task: arg.
The single axis is not init correctly. The sensor process is not
init correctly.
Program ref: arg.
41431, System Access Error
Description
Task: arg.
Unknown LOGSRV instance.
Program ref: arg.
Recommended actions
Restart the controller and retry.
41432, System Access Error
Description
Task: arg.
Cannot set test signals.
Program ref: arg.
Recommended actions
Restart the controller and retry.
41433, Parameter Error
Description
Task: arg.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
Unknown mechanical unit.
Program ref: arg.
Recommended actions
Check if the mechanical unit exists in the system.
Recovery: arg.
41434, Parameter Error
Description
Task: arg.
Argument Axis is out of range.
Program ref: arg.
Recommended actions
Check and change the value of the argument axis.
Recovery: arg.
41435, Parameter Error
Description
Task: arg.
Argument Channel is out of range.
Program ref: arg.
Recommended actions
Check and change the value of argument Channel.
41437, System Access Error
Description
Task: arg.
Cannot reset all test signals.
Program ref: arg.
Recommended actions
Restart the controller and retry.
41438, Undefined Load
Description
Task: arg.
WARNING! Argument arg has undefined load (mass=0).
Program ref: arg.
Consequences
IMPORTANT TO DEFINE CORRECT LOAD to avoid mechanical
damages of the robot.
Recommended actions
Define the actual load for the tool or the grip load before
program movement or jogging. A good motion performance
requires a correctly defined load.