5 Troubleshooting by event log
5.12 13 xxxx
Continued
Recommended actions
1. Check if flushing of system is
performed.
2. Check if potlife time is correct.
133214, arg:Setp. hi
Description
Setpoint value for named device is too
high. The setpoint value is set to
the maximum configured value for named
device.
Recommended actions
1. Check if setpoint to named device
is set too high.
2. Change the maximum value in the
IPS config file if needed.
133215, arg:Setp. lo
Description
Setpoint value for named device is too
low. The setpoint value is set to
the minimum configured value for named
device.
Recommended actions
1. Check if setpoint to named device
is set too low.
2. Change the minimum value in the
IPS config file if needed.
133216, arg:Seq. error
Description
IPS has discovered a trig sequence
error. The Dynamic Delay Compensation
function for named device measured an
'on'- transition while expecting an
'off'- transition. (Or opposite)
Recommended actions
1. Check if the sensor signal
has the correct level.
2. Check if the sensor signal
is noisy.
133217, arg:Unexp. trans.
Description
IPS has discovered an unexpected
Continues on next page
548
transition. The Dynamic Delay
Compensation function for named device
measured a transition at a time when
none was expected.
Recommended actions
1. Check relay and electrical
connections for the sensor.
2. Check if the sensor signal
is noisy.
133218, arg:Timeout On
Description
IPS has discovered a trig timeout
for an 'on'- transition. The Dynamic
Delay Compensation function has timed
out for an 'on'- transition.
Recommended actions
1. Check sensor for named device.
2. Check wiring or relay for sensor.
133219, arg:Timeout Off
Description
IPS has discovered a trig timeout
for an 'off'- transition. The Dynamic
Delay Compensation function has timed
out for an 'off'- transition.
Recommended actions
1. Check sensor for named device.
2. Check wiring or relay for sensor.
133220, arg:No signal
Description
IPS is reading a zero value from the
sensor used by the named device. Wiring
or supply to this sensor can be
the reason.
Recommended actions
1. Check if used sensor is broken.
2. Check wiring of used sensor.
3. Check process supply for used sensor.
133221, arg:Max output
Description
The closed loop regulator for named
© Copyright 2005-2018 ABB. All rights reserved.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA