ABB IRC5 Operating Manual page 369

Troubleshooting
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

The maximum number, arg, of user I/O signals in the I/O system
has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the
number of I/O signals) so that the maximum limit is not
exceeded.
71083, Max number of symbols exceeded
Description
The I/O configuration is invalid.
The maximum number, arg, of symbols in the I/O system has
been exceeded.
The number of symbols is the sum of all named configuration
instances: Industrial Networks I/O Devices Device Trust Levels
I/O Signals Commands Access Levels Signal Safe Levels Cross
Connections Routes
Recommended actions
Modify the configuration of the I/O system (by reducing the
number of symbols) so that the maximum limit is not exceeded.
71084, Max number of subscribed I/O signals
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg, of subscribed I/O signals in the I/O
system has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the
number of subscriptions) so that the maximum limit is not
exceeded.
71085, Max number of I/O devices exceeded
Description
The I/O configuration is invalid.
The maximum number, arg, of I/O devices in the I/O system
has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the
number of I/O devices) so that the maximum limit is not
exceeded.
71098, NFS server lost
Description
The contact with the NFS server arg is lost.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
Recommended actions
The NFS server. The network connection. The NFS client.
71099, Trusted NFS server lost
Description
The contact with the trusted NFS server arg is lost.
Recommended actions
The NFS server. The network connection. The NFS client.
71100, Max number of Industrial Networks
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg, of Industrial Networks in the I/O
system has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the
number of Industrial Networks) so that the maximum limit is
not exceeded.
71101, Network undefined
Description
The I/O configuration for I/O device arg is invalid.
The network arg cannot be found in the system. An I/O device
must refer to a defined network.
Installed Industrial Networks are:arg arg arg
Consequences
This I/O device has been rejected, and no functions depending
on it will work.
Recommended actions
Make sure the network is defined. Make sure the network name
is correctly spelled.
71114, Invalid IP address
Description
The IP address arg is not valid.
Recommended actions
Check the Communication configuration.
71115, Invalid subnet mask
Description
The subnet mask arg is not valid.
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
Continues on next page
5.8 7 xxxx
Continued
369

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents