5 Troubleshooting by event log
5.10 11 xxxx
Continued
110120, Weave bias change too big
Description
Task: arg
The weave bias change is bigger than allowed.
Max arg [m]
Recommended actions
Adjust weave tuning increment for bias, and/or check that the
change of the bias is less than the maximum.
110121, Weave width tuning error
Description
Task: arg
The weave width change is bigger than allowed.
Max arg [m]
Recommended actions
Adjust weave tuning increment for width, and/or check that the
change of the width is less than the maximum.
110122, Weave height tuning error
Description
Task: arg
The weave height change is bigger than allowed.
Max arg [m]
Recommended actions
Adjust weave height tuning increment, and/or check that the
change of the height is less than the maximum.
110130, Signal not defined
Description
Task: arg
The signal arg is not defined.
arg
Recommended actions
Define the signal arg in eio.cfg
110131, No Signal specified
Description
Task: arg
No signal specified!
arg
Recommended actions
Specify a DI signal
Continues on next page
456
110132, An internal error occurred
Description
Task: arg
arg
Recommended actions
Check the 'Internal' Log.
110133, Wrong path level
Description
Task: arg
arg
This instruction is not allowed on this path level (arg).
Recommended actions
Use RestoPath, to change to path level 0.
110134, Change from fine to z0
Description
Task: arg
arg
A 'fine' point is not allowed in the middle of a Process sequence.
The zone data was changed from 'fine' to 'z0'.
Recommended actions
Correct your RAPID instruction's zone data.
110135, Capdata.first_instr changed to FALSE
Description
Task: arg
arg
A capdata.first_instr = TRUE is not allowed in the middle of a
Process sequence.
The value is internally changed from 'TRUE' to 'FALSE'.
Recommended actions
Correct your RAPID instruction's capdata.first_instr value or
review the Cap sequence.
110140, \ReportAtTool only allowed with Look
Ahead Trackers
Description
Task: arg
arg
It is not allowed to use the optional argument \ReportAtTool
with other sensors than Look Ahead Trackers (e.g. Laser
Trackers).