Recommended actions
Create the device manually.
71545, Network auto configuration, device,
successful
Description
The network auto configuration, operation: add I/O device(s),
on network arg was successful.
View the information in the Event log.
Recommended actions
Restart the controller to activate the new I/O device(s).
71546, Network auto configuration, device, not
successful
Description
The network auto configuration, operation: add I/O device(s),
on network arg was not successful.
Recommended actions
View the errors in the Event log.
71547, Network auto configuration, device and
signals, successful
Description
The network auto configuration, operation: add I/O device(s)
and I/O signals, on network arg was successful.
View the information in the Event log.
Recommended actions
Restart the controller to activate the new I/O device(s) and I/O
signals.
71548, Network auto configuration, device and
signals, not successful
Description
The network auto configuration, operation: add I/O device(s)
and I/O signals, on network arg was not successful.
Recommended actions
View the errors in the Event log.
71549, Overlapping I/O signals with different
values on ActionAtSysRestart
Description
The I/O signal arg has overlapping bit(s) in the device map with
the I/O signal arg.
Operating manual - Troubleshooting IRC5
3HAC020738-001 Revision: AA
The I/O signal arg is using Signal Safe Level arg and the I/O
signal arg is using Signal Safe Level arg.
I/O signals with overlapping device mapping must have the
same value on the Signal Safe Level parameter
ActionAtSysRestart.
Consequences
The I/O signal arg has been rejected, and no functions
depending on it will work.
Recommended actions
Correct the Signal Safe Level definitions for the overlapping
I/O signals in the I/O configuration.
71550, Overlapping I/O signals with differing
default values
Description
The I/O signal arg has overlapping bit(s) in the device map with
the I/O signal arg. The I/O signal arg is using the default value
arg and the I/O signal arg is using the default value arg.
I/O signals with overlapping device mapping must have default
values with equal values on overlapping bit(s).
Consequences
This I/O signal arg has been rejected, and no functions
depending on it will work.
Recommended actions
Correct the default values for the overlapping I/O signals in the
I/O configuration.
71551, Network auto configuration not supported
Description
Network auto configuration is not supported on network arg.
71552, Max number of device trust levels
exceeded
Description
The I/O configuration is invalid.
The maximum number, arg, of device trust levels in the I/O
system has been exceeded.
Recommended actions
Modify the configuration of the I/O system (by reducing the
number of device trust levels) so that the maximum limit is not
exceeded.
© Copyright 2005-2018 ABB. All rights reserved.
5 Troubleshooting by event log
Continues on next page
5.8 7 xxxx
Continued
397